Cleanroom interlock pass boxes (also known as pass through boxes or transfer windows) are essential material-transfer equipment used to move items between cleanrooms of different cleanliness classes, or between a cleanroom and a general area, while minimizing cross-contamination risk. Built with an electromagnetic or mechanical interlock system, our pass boxes ensure that only one door can be opened at a time, maintaining pressure differentials and preventing airflow disturbance between zones. Widely used in pharmaceutical plants, biotechnology laboratories, hospitals, electronics manufacturing, and food processing facilities, these units are typically constructed from 304 or 316L stainless steel for corrosion resistance, durability, and ease of cleaning, and can be customized in size, interlock type, and UV configuration to match specific process requirements.
Send Inquiry
Product Details ofCleanroom Interlock Pass Box & Pass Through Box

Floor Standing Cleanroom Interlock Pass Box & Pass Through Box

1. Material Transfer Window (Static Pass Box)

Function: Transfers materials into the cleanroom while limiting particle and microbial ingress.

Airflow direction: Unidirectional - General area → Class C clean area.

Operating notes:

  • Materials should not overload the chamber in a single transfer, to allow adequate UV exposure and airflow stabilization.
  • UV irradiation for 30 minutes is required before use (except for materials that are UV-sensitive or cannot tolerate UV exposure).
  • After each use, wipe down the interior with 75% ethanol and irradiate with UV for 30 minutes to maintain a controlled, low-bioburden environment.

 

Long cleanroom corridor with multiple stainless steel pass boxes

 

2. Waste Transfer Window (Waste Pass Box)

Function: Passes waste and used materials out of the clean area.

Airflow direction: Unidirectional - Class C clean area → General area.

Operating notes:

  • After each use, clean the interior surfaces with 75% ethanol and irradiate with UV for 30 minutes to prevent contamination carryover.

Cleanroom Interlock Pass Box & Pass Through Box

 

stainless steel pass through box

floor standing Stainless steel cleanroom pass box

 

3. Blood Product Delivery Window (Bi-Directional Pass Box for Blood Samples)

Function: Transfers blood samples, finished blood products, and inspection samples between clean and general areas.

Airflow direction: Bi-directional - Class C clean area ⇄ General area.

wall-mounted stainless steel interlock pass box

floor-mounted stainless steel interlock pass box

 

4. Frozen Sample Transfer Window (Cold Chain Pass Through Box)

Function: Transfers frozen, cryopreserved, resuscitated, and other temperature-sensitive sample products.

Airflow direction: Bi-directional - Class C clean area ⇄ General area.

Operating notes:

  • Turn on UV irradiation for 30 minutes before use, then switch off the UV lamp during actual transfer operations.
  • After use, clean with 75% ethanol and irradiate with UV for 30 minutes to maintain sample integrity and chamber sterility.

 stainless steel cleanroom pass through box embedded in a wall

 

 

Product Features & Construction

1

Material: 304 / 316L stainless steel body with sandblasted or mirror-polished finish for superior corrosion resistance and easy sanitization

2

Interlock system: Electromagnetic or mechanical interlock prevents both doors from opening simultaneously, preserving pressure differential between zones

3

Sealing: Silicone door gaskets provide reliable airtight sealing to reduce particle infiltration

4

UV sterilization: Built-in UV lamp with adjustable timer for automated disinfection cycles

5

Viewing window: Optional tempered glass viewing panel for visual confirmation without opening the chamber

6

Safety design: Interlocking mechanism and optional alarm/indicator lights reduce the risk of cross-contamination from operator error

7

Load capacity & sizing: Available in a range of internal dimensions and shelf load capacities to accommodate different material sizes and weights - details available on request based on application

 

 

Applications

 

 

Cleanroom pass boxes are commonly specified for:

  • Pharmaceutical manufacturing and GMP cleanrooms
  • Biosafety laboratories and biotechnology facilities
  • Hospitals, blood banks, and clinical testing areas
  • Electronics and semiconductor cleanrooms
  • Food and cosmetic production environments

 

 

Customization, OEM/ODM & Ordering Information

 

 

  • Configurations available: Static (single-direction) or bi-directional pass boxes; standard UV or UV + mechanical/electromagnetic interlock; with or without viewing window
  • Sizes: Custom internal and external dimensions available to fit wall openings and process layouts
  • OEM/ODM: Custom branding, labeling, and configuration available for bulk and project orders
  • Packaging & shipping: Units are typically wooden-crated or foam-protected for export shipment; sea and air freight options available depending on order volume and destination
  • After-sales support: Installation guidance, spare parts (UV lamps, gaskets, interlock components), and technical consultation available for overseas clients

Hot Tags: cleanroom pass box, pass through box, interlock pass box, cleanroom transfer window, stainless steel pass box, laboratory pass box, pharmaceutical pass box, GMP pass through window, blood sample transfer window, UV sterilization pass box, static pass box, dynamic pass box, clean room equipment manufacturer